Notifiers intelligent addressable control module provides supervised monitoring of wiring to load devices that require an external power supply to operate such as horns strobes or bells. Secure module to electrical box supplied by installer as shown in figure 2a.
Fire Alarm Wiring Based On Nec Article 760 Fire Alarms Online
Notifier cmx 2 wiring diagram. Notifier notifier xp6 r six relay control module 34000. All wiring must conform to applicable local codes ordi nances and regulations. Typical 4 wire fault tolerant initiating circuit configuration nfpa style d cmx 2a control module wiring diagrams communication line connect modules to listed compatible notifier control panels only from panel or previous device all wiring shown is supervised and power limited 32 vdc max. The relay module allows the control panel to switch two isolated sets of form c contacts on command. Are available from notifier. Set the address on the m300 and c304 per job drawings.
Notifier nfs manual online. This module can be used to replace a cmx 2 module that has been configured for supervised wiring operation151. Mounting mmx 1a cmx 2a and iso x devices mmx 1a cmx 2a and iso x modules mount directly to 4 inch square electri cal boxes as shown in figure 2a. You must be logged in to post a review. The box must have a minimum depth of 218. A78 2286 09 current rating maximum voltage load.
It is capable of class a and class b supervision. All wiring must conform to applicable local codes ordinances and regulations. When using control modules in nonpower limited applica. As a result existing nonaddressable loops can be integrated into a notifier addressable system the module monitors a zone of two wire non addressable smoke detectors. Record this ad dress and loop on the front of the module if desired. Communicate with a notifier analogue addressable system.
Notifier notifier fmm 101 addressable monitor module. When using control modules in. Our notifier cmx 2 addressable control module in new condition comes with a warranty of 90 days and fast shipping via ups. Relay module wiring diagram. Each m710 czr uses one of 99 available module addresses on a loop. Notifier cmx 2 control module wiring diagram division of pittway corporation mmx 1a monitor module cmx 2a refer to the appropriate notifier installation manual for detailed system information.
Notifier by honeywell is the largest manufacturer of engineered fire alarm systems with over 400 distributors worldwide and regional support operations on every continent. Be the first to review notifier cmx 2 addressable control module cancel reply. Connecting a releasing device to the fcm 1 rel. Install module wiring in accordance with the job drawings and appropriate wiring diagrams figures 3 10. 16112018 16112018 3 comments on notifier fcm 1 wiring diagram. This module can be used to replace a cmx 2 mod ule that has been configured for form c operation.