Gsk 3 spill switch installation manual. Connect the supplied 14 aluminum tubing to the tubing connector.
Swg Power Vent System Leisure Line Stove Company
Swg power vent wiring diagram. The burner motor on the primary to the pv control then back to the burner motor instead of just directly from the high limit b1 on aquastat. Concealed wiring or plumbing inside walls. Route the tubing to the ck 61. See figure 3 2. The swg mounts on the outside of the building and pulls the combustion gas from the appliance through the outside wall utilizing 100 negative pressure. See figure 4 2.
Connecting power venter to appliance figure 3 figure 4 diagram a 3. Single wall vent pipe refer to diagram b may be used to join an appliance to the venting system but if. Tems included in kit 1 junction box with mounted pressure switch and solid state post purge control 1 2 ft. Swg swg stainless series patented. Mount the power venter through the wall keeping the outer pipe centered in the hole. Electrical power supply to the appliance when wiring the blocked vent switch.
I always wonder about 2 things when wiring this power venter or any combustion air system for oil in this example. Why does the signal come from. Ck 61 designed for use on swg series power vent hoods for controlling oil fired heating appliances with 120 vac controls. Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage. Installation manual for model gsk 3 spill switch. The swg power venter approximately 1 long.
If proper clearances cannot be maintained from combustible material type b vent pipe should be. Single wall vent pipe refer to diagram b may be used to join the appliance to the power venter. Mounting location on an mg 1 4 9 barometric draft control. Looking at the diagram. Installation manual and wiring diagram for model swg 4l power venter for lennox g23 g24m and 80mgf series units. This equipment is designed to overcome minor.
Pressure switch sensing tube installation 1. Page 1 120 vac system control kit model. Sidewall power venter kit model. If you wire it to power from b1 on the aquastat instead of from the output on the cad cell this may help. With some of the new prepost purge controls you can get bleed by voltage that will turn the power vent on without the burner. 100 negative pressure in the vent pipe for maximum safety.
Replaced 15 year old field swg 4 power venter with new one had a problem with old control not working right had to fix for safety reasons cleaned oil fired. Attach the 14 inch tubing connector to the pressure tube on the swg venter. After determining the location of the venting system termination point see diagram a cut a square hole through the wall 1 larger than the outer pipe diameter of the power venter. Benefits of the swg power venter include. The swg combines the motor blower and vent hood in one complete easy to install unit. Power vent i would check the wiring.
Attach the vent pipe over the crimped.