If the 4 wire dryer receptacle will be replaced with a 3 wire dryer receptacle then the white neutral is capped off and not used the ground wire is attached to the angle plug of the receptacle typically identified with a g and the red and black wires are connected to the remaining x. Yellow wire white the 4 prong dryer outlet wiring diagram above is ran with a 103 with ground cable.
Where Does The Ground Wire Go In A 3 Prong Dryer Cord
Dryer cord wiring diagram. Due to changes in the national electrical code nec recommended wiring for electric clothes dryer outlets changed in 1996before the change dryer outlets were 3 slot devices that accepted 3 prong cords. It reveals the components of the circuit as streamlined forms and the power as well as signal links in between the devices. Two hot wires and the third contained both ground and a neutral wire. Additionally wiring diagram gives you time body by which the projects are to become accomplished. The dryers equipment ground case ground was connected to the neutral conductor in the dryer cord and the household circuit. The center wire if a 3 wire dryer cord is the ground wire.
This article will explain what options you have to get your dryer wired and running. In this amazing episode of appliantology tv samurai appliance repair man shows you the right way contrasted with the wrong way to wire a dryer terminal block for the 4 wire dryer cord. 3 prong cord attach the middle or ground wire to the center terminal one of the outer wires to the right terminal and the other outer wire to the left terminal. Consult the dryer wiring diagram in the user manual. 4 wire dryer wiring data wiring diagram schematic 4 prong dryer outlet wiring diagram. This configuration did not include a dedicated ground connection.
Before 1996 electric dryers were supplied by a dedicated circuit that had three conductors. This system worked pretty well and is still in use in many homes today but there is more potential for electrical. Collection of maytag dryer wiring schematic. A wiring diagram is a simplified standard pictorial depiction of an electric circuit. As you can see there is now an added dedicated neutral. Electrical wiring for a dryer power cord has a typical 240 volt electric power cord with 3 wire and 4 wire wiring configurationsmany people may experience the situation of trying to make a older dryer work with an new four wire receptacle.
There was no dedicated ground slot on the receptacle outlet and dryer cords had no ground wire or ground prong. But if you notice both the neutral and the ground wires both connect to the same ground bar inside the panel box. Youll be capable to understand specifically if the tasks needs to be accomplished that makes it much easier for you personally to properly handle. The ground is now a dedicated wire also.