Addressability al lows the fcm to be activated either manually or through. An automatic fire alarm systemtypically made up of smoke detectors heat detectors manual pull stations audible warning.
8 Loops 2592 Points Addressable Fire Alarm System Fire
Fire alarm control module wiring diagram. Module polarities are shown in alarm connect modules to listed compatible 32 vdc max. 2 firelite slc wiring manual pn 51309r2 3192019 fire alarm emergency communication system limitations while a life safety system may lower insurance rates it is not a substitute for life and property insurance. Fire alarm security access control cctv published by edwards systems technology in conjunction with paige electric co lp. Siga im 70 audio. Install module wiring in accordance with the job drawings and appropriate wiring diagrams figures 3 10. Level 0 means no survivability is required wiring within the esz level 1 3 indicate that attack by fire shall not impair the control and operation of notification appliances outside the esz.
Break wire run to provide supervision. The circuit type is designated with a letter a z. 5 for frm 1 general fcm 1 control module the fcm 1 addressable control module provides notifier intelligent control pan els a circuit for notification appliances horns strobes speak ers etc or to monitor a telephone circuit. Fire alarm control module wiring diagram wiring diagram is a simplified customary pictorial representation of an electrical circuit. Box and the control module must be placed into the barrier and at tached to the junction box figure 2a. It shows the components of the circuit as simplified shapes and the capacity and signal associates together with the devices.
Fire alarm system is the combination of different components such as smoke detector heat detector carbon monoxide detector multi sensor detector call points sounders bells relay module repeater annunciator fire control panel and other related and optional security devices designed for fire alarm control system. One relay required for each circuit. The information shown for each control panel includes wiring diagrams and circuit tables. Refer to notifier manual. Fcm 1 module see wiring diagram fig. The power limited wiring must be placed into the isolated quadrant of the module barrier figure 2b.
An esz is a discrete area of a building bounded by smoke or fire barriers in which occupants are intended to relocate or evacuate. Is recommended 24 vdc circuit 3 4. To next control module or end of line relay. Siga rel 69 isolator module. Some control panels have relay built in and do not require external wiring.