Frm 1 wiring diagram. It allows a compatible control panel to switch discrete contacts by code command. Fmm 101 mini monitor module. It reveals the parts of the circuit as streamlined forms and the power as well as signal links in between the tools. Install module wiring in accordance with the job drawings and appropri ate wiring diagrams. All wiring shown is supervised and power limited. Removing rotary switch stop.
The frm 1 mounts directly to 4 square electrical boxes see fig ure 2a. Maximum slc current draw. Connect modules to listed compatible notifier control panels only. 4675 h x 4275 w x 14 d mounts to a 4 square by 218 deep box specifications for frm 1. Page 1 figure 1. Class a supervised wiring to the monitored device.
Typical notification appliance circuit configuration nfpa style y. Set the address on the module per job drawings. The power limited wiring must be placed into the isolated quadrant of the module barrier figure 2b. Variety of notifier fcm 1 wiring diagram. 32f to 120f 0c to 49c dimensions. A78 2611 11 a78 2610 08 specifications normal operating voltage.
The frm 1a provides two form c dry contacts that switch together. All wiring shown is supervised and power limited. Install contact closure devices per manufacturers installation instructions. Fmm 1 connect modules to listed compatible notifier control panels only. Module polarities are shown in alarm. Class b supervised wiring to the monitored device.
Fzm 1 zone interface monitor module. 15 to 32 vdc. The frm 1 relay control module is intended for use in intelligent two wire systems where the individual address of each module is selected using the built in rotary switches. The fcm 1a is configured for a single class b style y or class a style z notification appliance circuit. 15 to 32 vdc. Relay module wiring diagram.
Operation each fcm 1a or frm 1a uses one of 159 possible module addresses on a slc loop 99 on clip loops. Maximum slc current draw. Install module wiring in accordance with the job drawings and appropriate wiring diagrams. Page 5 wiring diagrams this page. Any number of ul listed contact closure devices may be used. 65 ma led on temperature range.
A wiring diagram is a simplified conventional pictorial representation of an electric circuit. Secure module to electrical box supplied by installer see figure 2a. Module mounting with barrier. Transmits the status of one zone of 2 wire detectors to the fire alarm control panel. Typical fault tolerant notification appliance circuit configuration nfpa style z. When using control modules in.
The box must have a minimum depth of 21 8. Smaller size fits inside devices or junction boxes. Removing general description rotary switch stop. Surface mounted electrical boxes smb500 are available from notifier. 15 to 32 vdc maximum current draw.