Photograph of istar pro gcm acm module figure 3. Tyco istar ultra pdf user manuals.
Acm Wiring Diagram Bmw 49 Althausbittetzutisch De
Istar ultra acm wiring diagram. This chapter provides the information you need to set up an istar or apc installation that includes rm 4 hardware. Aperio hubs and readers per gcm rs 485 comm port 22. Rs 485 terminators when dry the integrator must supply the external power that the relay switches. Combines fixings for istar ultra gcm and 2 x acm with power for controllers locks and readers. When used in pro mode the istar ultra se has the same capabilities as the istar pro and is compatible with ccure 8008000 and ccure 9000. These power outputs can be converted to dry form c contacts.
Istar ultra is a powerful network ready door controller built on the linux platform that supports up to 32 readers. View online or download tyco istar ultra installation and configuration manual. Photograph of istar pro acm. Io per acm 23. Featuring advanced encryption and backup communication paths the istar design is among the industrys most reliable and secure. Istar ultra se is a special edition istar ultra door controller that supports up to 32 readers and combines istar ultra features with a pro mode that ensures flexibility and compatibility with all software house access control systems.
The suite of istar door controllers provides powerful network ready solutions for enterprise wide access control. Ustar016 istar ultra controller for 16 readers wall mount housing with general controller module and two access control module or up to 16 readers wiegand or rm. Istar classicpro acm istar ex gcm apc wpsc reader wiring specifications table 5 shows reader wiring specifications. Sw32 1 off acm is unit 0 zero sw32 1 on acm is unit 1 istar ultra installation and configuration guide 65. Page 4 this section describes the power requirements for the istar pro. Ac power the istar pro input power rating is 100 240 vac 23a max 47 63 hz.
This powerful controller supports both traditional hard wired and wireless locks all in the same controller. Houses 3 x vrla batteries up to 17ah capacity. Wet wiring for a magnetic lock. Reader wiring specifications signal from to belden gauge prs shielded max length reader data rm 4e rm 4 pro acm ex gcm or wpsc wiegand read head 9942 9260 alpha wire 5386c 22 20 18 3 yes 200 ft. The system current draw is 23a at 100vac or 11a max at 240vac 47 63hz. The istar pro istar ultra and istar ultra se models are also available in space saving rack mount modelsbrbrp.
To connect ac power. Of the 32 supported readers 16 may come from the access control modules acm io units the rest can be made up of wireless lock sets and devicesbrbrrack. The istar ultra will supply 0. Altronix acm8 converts one 1 12 to 24 volt ac or dc input into eight 8 independently controlled fuse protected outputs. Io per gcm 23. 6096 m 300.
Installing the rm 4 this chapter provides detailed rm 4 component diagrams overviews the installation procedure and provides detailed installation instructions. Wet relay wiring figure 6 12 on page 6 14 shows wet wiring for a normal no latch.