Some control panels have relay built in and do not require external wiring. Install module wiring in accordance with the job drawings and appropri ate wiring diagrams.
Wiring Diagram For 98 Tahoe 98 Tahoe
Notifier control module wiring diagram pdf. Notifier cmx 2 addressable control. The power limited wiring must be placed into the isolated quadrant of the module barrier figure 2b. Install module wiring in accordance with the job drawings and. Addressability allows the fcm 1a to be acti vated either manually or through panel programming on a select zone or area of coverage basis. Box and the control module must be placed into the barrier and at tached to the junction box figure 2a. This module is intend ed for power limited wiring only.
Refer to the appropriate notifier control panel installation note. Addressability al lows the fcm to be activated either manually or through. Typicalnotifier system control panel only list available from notifier. Fcm 1 module see wiring diagram fig. Refer to notifier manual. 5 for frm 1 general fcm 1 control module the fcm 1 addressable control module provides notifier intelligent control pan els a circuit for notification appliances horns strobes speak ers etc or to monitor a telephone circuit.
Trol module provides notifier intelligent fire alarm control pan els a circuit for notification appliances horns strobes speakers etc. Install module wiring in accordance with the job draw ings and appropriate wiring diagrams. Scs 8 fan control module annunciator. Some panels support. Is recommended 24 vdc circuit 3 4. Install module wiring in accordance with the job drawings and appropriate wiring diagrams figures 3 10.
Our notifier cmx 2 addressable control module in new condition comes with a warranty of 90 days and fast shipping via ups. Some panels support this module can be used to replace a cmx 2 mod a ule thatdisconnect power to the control panel before installing the modules. The frm 1a addressable relay. Break wire run to provide supervision. All wiring must conform to applicable local codes ordinances and regulations. Set the address on the module per job drawings.
Module polarities are shown in alarm connect modules to listed compatible 32 vdc max. To next control module or end of line relay. 15 to 32 vdc. Module does not supervise controlled. The frm 1 relay control module is intended for use in intelligent two wire systems where the individual address of each module is selected using the built in rotary switches. Intelligent addressable control module and relay with built in type identification for onyx series panels.
Notifier cmx 2 control module wiring diagram division of pittway corporation mmx 1a monitor module cmx 2a refer to the appropriate notifier installation manual for detailed system information. 65 ma led on. Set the address on the module per job drawings. In addition this module is intended for powerlimited wiring only. Notifiers intelligent addressable control module provides supervised monitoring of wiring to load devices that require an external power supply to operate such as horns strobes or bells. One relay required for each circuit.