I opened the pool sub panel and it seems that whoever wired the gfci might have wired it incorrectly or upside down ie the line and loads wires were at the bottom and load were at the. Refer to the diagram above about wiring gfci receptacles for additional help.
Replacing Pool Light Switches With Smart Switches Is This
Pool light gfci wiring diagram. In a situation like this it would be best to have a licensed electrician install the necessary gfci protection for the pool light and at the same time take a look at all of the electrical wiring and devices in the area of the pool and then make recommendations about anything that is not up to current electrical code standards. In this gfci outlet wiring and installation diagram the combo switch outlet spst single way switch and ordinary outlet is connected to the load side of gfci. It includes instructions and diagrams for various varieties of wiring methods as well as other items like lights windows and so on. I bought a new smart lock gfci and wired it up correctly. The neutral and ground wires are spliced together and run to each device in the circuit. The hot source is spliced to the line terminal on the receptacle and to one terminal on the light switch.
I used a circuit tester and it reported a hot neutral reverse. Is this setup okay. Loosen the silver and brass terminal screws on the line side of the outlet. Gfci can now setreset pool light switch works fine and circuit tester reports correct wiring. 12v pool light wiring diagram trusted wiring diagram online pool light wiring diagram wiring diagram includes many detailed illustrations that display the relationship of assorted products. Wiring a gfci outlet with combo switch outlet receptacle light switch.
If more than 1 black and 1 white conductor are in the electrical box also loosen the load side silver and brass terminal screws. View attachment visio aqualink rs light wiringpdf i found this installation manual of the aqualink rs on line see pages 12. This diagram illustrates wiring a gfci receptacle and light switch in the same outlet box a common arrangement in a bathroom with limited space. All ground wires green should be tied to the grounding bar. Gfci protection is required for all 120v to 240v single phase pump motors. I noticed i was not able to reset the gfci but the pool light and receptacle kept working.
I am attaching a diagram of what i think you should have. Wiring a light switch diagram 1. Gfci protection is required for all underwater lighting operating over the low voltage contact limit. Gfci protection is required for all receptacles that supply power to the pool equipment such as water heaters and pump motors. It means all the connected loads to the load terminals of gfci are protected. The neutrals whites of the pool and spa lights get tied back to the gfci load side neutral.
How to wire gfci outlets gfci and gfi wiring diagrams. I noticed the wiring layout seemed a little odd so i put a diagram to explain the layout a little better. The features and benefits of gfci outlets and receptacles will give you a clear understanding of the importance why these safety devices are required by code to help protect you and your family against accidental electrical shock hazards. I have a pool light and a two plugs receptacle connected to a gfci.