16 awg 131mm2 is the largest wire that can can be brought into the hmi socket contact pins. See the wiring schematic in figure 5.
Cummins Ed 3 Installation Manual Manualzz
Power command hmi211 wiring diagram pdf. Prevent leaks and the accumulation of gas. Select the appropriate wire size from table 1. 1 j1 and j2 wiring connectors 2 p1 harness plug figure 3. Inscreva se e deixe o seu like. Generation distributor for more information. Section title page control box wiring 3 31 run relays k11 k12 k13.
The powercommand control system is a power for this control system is derived from the generator set starting batteries. Operator and installation manual remote network monitoring powercommand iwatch 100 english 12 2007 9000545 issue 3. A051x877 issue 3 1. See the wiring schematic below. A rotten egg smell indicates a possible natural gas or propane leak. Propane sinks when released and can accumulate inside housings and.
In the event that this manual has been supplied in isolation please contact your authorized dealer. Wiring and terminal block customers need to supply wiring to connect the re mote hmi to the controller or the separate power supply. If the distance is greater than 500 feet power must come from an isolated 12 or 24 vdc power supply with 3 amp overcurrent protection. The hmi 211 can be powered from pcc 1302 if within 500 feet 152 meters. It is power command hmi wiring diagram if you like to secure all of these fantastic pictures related to power command hmi wiring diagram click on save link to save the graphics to your pc. Connecting the hmi 211 remote no.
Natural gas rises when released and can accumulate under hoods and inside housings and buildings. Wiring schematic table 1. Contact your authorized cummins power ing sparking smoking etc. Powercommand controller owners manual try the power command hmi wiring diagram and follow every detail in the picture. Page 4 lead acid batteries emit a highly the genset are solely responsible for operating the gen explosive hydrogen gas that can be ignited by arc set safely. If greater than 500 feet power must come from an.
Realização de teste com carga em grupo gerador de 86 kva motor cummins 4b. Power generation with specific generator sets. Description 1 tb15 2 tb1 figure 4. The wire size required depends upon the distance between the two connections. Notice it is in the operators interest to read and understand all warnings and cautions contained in the documentation relevant to the generator set operation and daily maintenance. Pcc 1302 terminal blocks tb1 and tb15 6.
Leaks can lead to explosive accumulations of gas. The hmi211 rs can be powered from the pcc1302 if it is within 152 meters 500 feet.