Do not use b wire if you already have o wire. 5 connect wires alternate wiring if labeled wire does not match any terminal designation see diagram below.
Honeywell Thermostat Troubleshooting We Answered Each Query
Rth111b1024 u1 wiring diagram. Just set it to the temperature you want and adjust it up or down as desired. Wiring assistance troubleshooting 5 5 m32768 system setup note. Do not use c c1 or x wire. View and download honeywell rth111 user manual online. Press the s or t button to change the setting. Wrap bare end of wire with electrical tape.
From smart wifi thermostats with room sensors and humidification control to programmable and non programmable thermostats resideo products meet a variety of needs. This thermostat cannot be used if your old thermostat had any two of the following wires. If its a new installation you may have to identify the wires first. For more than a century honeywell thermostats have been the popular choice of homeowners. See pages 1517 to change function settings. Digital non programmable thermostat rth111b1024 read user manual online or download in pdf format.
Wrap bare end of wire with electrical tape. R rc rh 4 and v. A non programmable thermostat provides simple control of your heating and cooling system. Alternate wiring if a labeled wire does not match any terminal designation see diagram below. Wrap bare end of wire with electrical tape. 3ø wiring diagrams 1ø wiring diagrams diagram er9 m 3 1 5 9 3 7 11 low speed high speed u1 v1 w1 w2 u2 v2 tk tk thermal overloads two speed stardelta motor switch m 3 0 10v 20v 415v ac 4 20ma outp uts diagram ic2 m 1 240v ac 0 10v outp ut diagram ic3 m 1 0 10v 4 20ma 240v ac outp uts these diagrams are current at the time of publication.
Do not use b wire if you already have o wire. The honeywell rth111b is a programmable version of the honeywell rth111 thermostat series. Do not use c c1 or x wire. Rth111 thermostat pdf manual download. Do not use c c1 or x wire. Do not use b wire if you already have 0 wire.
Place a jumper piece of wire between y and. Alternate wiring quick installation guide connect wires contd alternate wiring if a labeled wire does not match any terminal designation see diagram below. If you do not press any button for 60 seconds while you are in the setup menu the thermostat automatically saves any changes made and exits the menu. When replacing an existing thermostat simply note the terminals to which the wires are attached and attach them to the same terminals. M32169a remove jumper between r and rc if you have wires on both r and rc.