Condensate has the potential to cause property damage or even create health hazards that can affect indoor air quality. Therefore the sanicondens range of pumps can help dispose of acidic condensate and neutralize odors.
Ac Condensate Pump Wiring Diagram Mercedesok 2 Rmnddesign Nl
Sanicondens condensate pump wiring diagram. Similar to sanicondens best but for use where a neutralising tray is not required. The sanicondens will pump condensate waste up to 15 feet in height andor 150 feet away from a soil stack. Sanicondens ecobasic has an earth wire. Do not connect sanicondens ecobasic to a conventional plug and socket. It must be wired into a fused unswitched fixed wiring connector fitted with a 5 amp fuse. When the condensate gathers in the tank the pump is activated.
The tank of the sanicondens best has a float which controls the pump. Shared wire 2 black wire. The product has its own neutralization tray to adjust the ph of the acidic water from the condensing boiler. Sanicondens plus is fitted with a detection system that can trigger an alarm if the water level rises too high audible of visual alarm 15v to 230v 1 brown wire. Step 4 remove the wire nut holding the thermostats red wire to one of the transformer low voltage wires and separate the two wires. This way if the condensate pump fails the safety switch yellow wires it will stop the furnaceac and no more water from condensate will be generated.
If heating or ac are a must then connect the yellow wires to an alarm. Condensate from boilers is not always able to drain away using gravity. Air conditioner condensate pumps are a convenient way to collect and dispose of the condensate produced by an air conditioning system when the air handlercooling coil are located in a building location where the cooling condensate cannot be drained away by gravity. The sanicondens ecobasic requires a 220240v single phase ac 50 hz supply uk specification. Normally on to fit the alarm connect the blue and brown wires of the alarm to the respective terminals on the sanicondens. The condensate pumps low voltage wire set contains two thin wires usually 18 gauge wire.
Normally off 3 blue wire. One connects to the ground lug and the other sends power to the thermostat. The sanicondens pro is specifically designed for disposal of acidic concentrate from boilers and other water producing equipment such as air conditioning units refrigeration units and dehumidifiers etc. The sanicondens best is a 2 in 1 condensate pump used to neutralize and pump condensate from condensing boilers hvac systems water heater systems etc. The sanicondens is a small pump used to pump condensate from condensing boilers hvac systems water heater systems etc. It is one of the most powerful and quiet condensate pumps on the market with standard features that no competitor can match.
Condensate pumps air conditioning condensate pump installation repair. The transformer has two low voltage wires. Includes a non return valve and 6m flexible discharge pipe. Cut the red wire from the furnace to thermostat and connect the yellow wires to the cut ends of the red wire. Sanicondens best is fitted with a second float that can control an alarm.