Printed in the united states of america. Hierfür vorbereitete zähler sind.
Elster Kent Helix H4000 Bulk Water Meter Range Accurate
Elster pr7 wiring diagram. 10 no output pr7 110 10 100 pr7 1100 10 1000 pr7 11000 10 10000 pr7 10100 100 1000 pr7 2550 250 500 dflag direction flag cflag compensation flag the pr7 pulser is used on the h4000 bulk meter as a result the pulse per litre high speed output is very quick. This module is tamper resistant and rated to ip68. For residential meters the battery life is designed to last for 12 to 14 years in normal use. Das impulsmodul pr6 wurde für elster ringkolbenzähler der baureihe v200 konstruiert. The baud rate set must match the baud rate for the given m. The meter consists of a 316 stainless steel flow tube 316 stainless steel joint pipes to extend lay length to awwa turbine or alternate lay lengths epoxy coated ductile iron flanges a 304 stainless steel.
Honeywell elster water is a global business which provides world class metering solutions and advanced technologies to help water utilities to manage their water. Suitable meters are marked with pr6 on the dial face or around the rim of the shroud. The pr6 is designed for elsters v200 range of domestic water meters and for some commercial meters which feature a plastic register. Falcon pr6pr7 m bus operating instructions falconmbm1404e0511 falcon m bus operating instructions 221008 generation 0a page 7 of 31 baudrate specifies the pcs interface speed. Notice the information contained in this software and documentation is subject to chan ge without notice. Heres a link to some common meter form wiring diagrams.
Without the express written consent of elster electricity llc. Here is a instruction manual for elster alpha series meters it has a larger selection of form wiring in the d section this file may take a while to download and you may need to click on refresh. Product specifications cited are those in effect at time of publication. Pr7 2550 25 50 pr7p10pr71010 100 100 pr7 1. It can be set to 300 600 1200 and 2400 baud and corresponds to the currently used m bus baud rate. Pr6 and pr7 pulsers are both easy and quick to fit to pre equipped elster water meters.
Fully self contained pr6 and pr7 pulsers do not need external power and are compatible with all major data loggers. Installation operation manual elster amco water llc date 5 31 2013 issue 2 page 6 of 30. Type retrofittable inductive pulse with 5m length cable compatibility h4000 c4000 c4200 elster water meters output primary secondary pulse. The pr7 pulse module is designed with advanced bi directional inductive technology helping to enhance the efficiency of network system management leakage control and reading of water meters remotely.