According to cummins newage the e000 23412 has a very minor change in the circuitry but they are interchangable with the e000 23410. Obscured by the customers wiring or other fittings.
Avr Mx341 Automatic Voltage Regulator Generator Purchasing
Mx341 avr wiring diagram. Signal injected into the avr and increases the droop with lagging power factor cos 0. Self excited automatic voltage regulator compatible with newage mx. Refer to alternator wiring diagram for connection details. The mx is a two phase sensed automatic voltage. Adjustment of the ufro potentiometer will only be necessary if the avr is being fitted to a 6 pole generator to replace an avr of an earlier type. The mx341 is provided as standard for the stamford.
It has improved motor starting performance and sustained short circuit current. Clockwise increases the amount of ct. The surface in the area where a label is to be stuck must be flat clean and any paint finish be fully. Is connected to s1 s2 on the avr see generator wiring diagram for details. Voltage regulator for newage mx341 cummins onan 305 0846 our vr341 voltage regulator is an exact replacement for stamford newage mx341 series part e000 23410. Mx341 is a two phase sensed automatic voltage regulator and forms part of the excitation system for a brush less generator.
The droop adjustment is normally preset in the works to give 5 voltage droop at full load zero power factor. The mx341 is an analogue 2 phase sensing permanent magnet generator pmg powered automatic voltage regulator avr providing isolation from the effects of non linear loads. Proudly powered by. Wiring diagramfitting and operating refer to generator wiring diagram for connection details mx avr outline drawing figure 1 newage mx avr 5. Mx341 is a two phase sensed automatic voltage regulator and forms part of the excitation system for a brush less generator. Will also replace the newer e000 23412.
Mx341 is a two phase sensed automatic voltage regulator and forms part of the excitation system for a brush less generator. Download mx341 wiring diagram. Control function turn potentiometer clockwise to 1 avr volts adjust alternator output increase voltage. Excitation power is derived from a three phase permanent magnet generator pmg to isolate the avr control circuits from the effects of non linear loads and to reduce radio frequency interference on the generator terminals. Excitation power is derived from a three phase permanent magnet generator pmg to isolate the avr control circuits from the effects of nonlinear loads and to reduce radio frequency interference on the generator terminals. A043y699 issue 2 5 ref.
Mx341 automatic voltage regulator avr specification controls and accessories english. 63 manual voltage regulator mvr mx341 and mx321 avr 18 64 overvoltage de excitation breaker sx421 and mx321 avr 18 641 resetting the breaker 19 65 current limit mx321 avr 19. See generator nominal frequency eg. The mx avr is a two phase sensed automatic voltage regulator and forms part of the excitation system for a brush less generator. Regulator avr provision is made for the connection of a remote voltage.