3 contents of the duct smoke. In canadian applications the rts451keya is intended to be located in the same room as the smoke detector and within 60 feet of the unit.
Rts151key A Remote Test Station System Sensor
Rts451key wiring diagram. Contacts cannot be used if they are wired to control panel. Wiring diagram for dh100acdclp to apa451. Power reset test red led alarm green led power dh100acdclp rts451rts451key 5 4 3. The rts151key mounts to a single gang box 2 12 minimum depth or directly to the wall or ceiling. Wiring diagram for rts151keya to d4120 4 wire duct smoke detector. Wiring diagram for rts151 to dnr 2 wire duct smoke detector with remote test capable head.
For 4 wire detectors the rts451key fea tures a multi colored led that alternates between steady. Wiring diagram for. Power reset test red led alarm green led power field installed jumper 12 1 12 1 interconnect unit 1 interconnect dh100acdclp dh100acdclp unit 2 rts451rts451key 5 4 3 interconnect interconnect note. Page 2 reset reset ra test v out no connection h0156 00 h0194 01 figure 4. 24v 120 a c 220240 ac 9 10 a c ailable power inputs alarm auxiliar contacts for fan shutdown etc. 21 detector feature set utilizes plug in head part number sk photor sampling tubes install from front and rear compatible with existing accessories able to address detector per code switches on sensor head.
16 17 7 18 8 nc. Wiring diagram for the rts451rts451key and interconnect feature 15 19 14 3 20 2 11 2 6 alarm signal 1 aux. Alarm auxiliar contacts shown in standby. Contacts transfer during alarm as. Capability with the rts451rts151 or rts451keyrts151key remote test stations. 15 19 14 3 20 2 11 2 6 alarm signal 1 aux.
The rts451key mounts to a single gang box 21 2 minimum depth or directly to the wall or ceiling. Wiring of rts451 consult the appropriate detector installation instructions for the applicable wiring diagram. Dh400acdc rts451key red led alarm alarm signal aux. Rts451rts451key rts151rts151key jumper 4 5 3 2 1 test coil test coil comm out conv only comm rarts ra rts h0633 00 figure 3. The rts451 mounts to a single gang box 21 2 minimum depth or directly to the wall or ceiling. 19 20 15 2 6 1 5 4 3 rts451keya d4120 green led power red led alarm field installed jumper 11 2 aux out aux out alarm r test r reset 14 3 sup no supc sup.
In canadian applications the rts151key is intended to be located in the same room as the smoke detector and within 60 feet of. For the applicable wiring diagram. Wiring instructions consult the appropriate detector installation instructions for the applicable wiring diagram. 46 h 275 w 15 d. Dh100acdclp rts451rts451key 5 4 3 for rts451key only without a control panel. Power for rts451key only without a sup.
Wiring diagram for rts451key to dh400acdc duct smoke detector. Rts451key wiring diagram wiring diagram is a simplified standard pictorial representation of an electrical circuit. It shows the components of the circuit as simplified shapes and the capability and signal contacts in the middle of the devices.