Current transformer wiring diagram instructions note. Summation ct when the currents in a number of feeders need not be individually metered but summated to a single meter or instrument a summation current transformer can be usedthe summation ct consists of two or more primary windings which are connected to the feeders to be summated and a single secondary winding which feeds a current.
Wiring Diagrams Hobut
Summation ct wiring diagram. The connection of the summation current transformer is shown in the figure below. The diameter of ct twisted pair lead wires is about 0213 in. Polarity must be observed if a primary ct is wired with the wrong polarity to summation ct its current will be subtracted from the total. Three twisted pair will fit in a 12 in. Summation auxiliary current transformer 22 specifying protection class current transformers in order to specify or check the ratings of a current transformer a thorough understanding of the application is required. Will be the vector sum of the two currents.
Neutral voltage protection 59gn 95 stator earth fault protection. It just reduces the metering complexity installation of multiple equipment cost wiring cost etc. Refer to the current transformer wire extension page for more information. The line cts are connected to the primary of the auxiliary ct. The two feeder currents may have individual magnitude and phase whereas the summated output from the summation ct. The summation ct consists of two or more primary windings which are connected to the feeders to be summated and a single secondary winding which feeds a current proportional to.
The secondary of the feeder ct of each feeder is connected to the summation ct. The sum of the all main. Ct ratio frequency etc. Summation current transformer is used when the currents in a number of feeders dont need to be individually metered but summated to a single meter or instrument. The diagrams below show the typical wiring schematic for various types of ct always follow the schematics and drawings issued for your particular installation always observe the polarity of the device that the ct is wired to measurement or protection ct only a single phase can be measured by each ct core balance or earth read more. Summation current transformer the main ct output from the various feeder is given to the common transformer.
Conduit might be a better. The above diagram shows the summation of two feeders 1 2 using a summation ct. This is about the diameter of a 8 awg thwn or thhn insulated conductor. If summation needs to be done on multiple phases then multiple summation cts are required. Conduit but if you are running any distance and have bends a 34 in. We supply these meters on the assumption that they will be installed by a qualified electrician familiar with the installation of metering equipment ensure all current transformers are installed as per wiringdiagram which can also be.
Each line cts energise the different number of turns on the primary side of the auxiliary cts. The resulting single phase output appears across the secondary. Please refer the diagram. With respect to ansi cts some of the major details that one would look for in the ct are. Summation cts can only be used across a single phase they cannot sum across multiple phases.