It transparently converts rs 232 signals into isolated rs 422 or rs 485 signals. Adam 4510i and 4520i offer internal surge protec tion on their data lines.
May 1 2018
Adam 4520 wiring diagram. Tough industrial design you can power adam 4510i and adam 4520 with any unregulated power source between 10 and 48 vdc. Adam 4520 converter function diagram adam 4510s repeater function diagram communication controller rs 422 rs 485 receiver driver direction control logic data 18432 mhz osc baud rate setting j2 data format setting j1 data1 data1 tx1 tx1 rx1 rx1 rs 485 rs 422 rs 232 receiver driver txd rxd rts gnd gnd gnd rect filter power. Terminals of the adam 5013 as shown in the following wiring diagram. Communication wiring we recommend that shielded twisted pair cables that comply with the eia rs 485 standard be used with the adam network to reduce. Inte rnal high speed transient suppressors on each data line protect the modules from dangerous voltages levels or spikes. 3292016 45551 pm.
Wiring diagram dse 4520 amf author. Sw2 switch 2 sets the baudrate. 1 2 adam 4000 series users manual introduction 11 overview the adam series is a set of intelligent sensor to computer interface modules containing built in microprocessor. Adam 45104510s4520 startup manual 3 baud rate settings sw2 adam 45104510s repeater module there is one led located on the top panel of adam 4510 4510s4520. Table 2 below shows the correct values of the span and zero calibration resistances to be connected. Accepts awg 1 12 or 2 14 22.
Figure 36 adam 40114011d digital output wiring diagram used with ssr hi lo alarm 28 figure 37 adam 40114011d digital input wiring diagram used with ttl28 figure 38 adam 40114011d digital input wiring diagram used. The factory default is 9600. They are remotely controlled. Though widely accepted rs 232 has limited transmission speed range and networking capabilities. Plug in screw terminal wiring. The adam 45204522 converter lets you take advantage of rs 422 and rs 485 on systems originally.
The rs 422 and rs 485 standards overcome these limitations by using differential voltage lines for data and control signals. Application wiring of each adam 5000 io modules. The options range from 1200 bps to 1152 kbps. Its purpose is to show the communication status. Most industrial computer systems come with standard rs 232 serial ports. 1200 bps 2400 bps 4800 bps 9600 bps 192 kbps 384 kbps 576 kbps 1152 kbps rs 422 2 4 1 2.
To organize an adam 5510 series controller you need to select io modules. Adam 45204522 converter lets you take advantage of rs 422 and rs 485 on systems originally equipped with rs 232. Adam 4520 rs 232rs 485 converter module. Adam 4520 converter function diagram adam 4510s repeater function diagram.