Is recommended 24 vdc circuit 3 4. Fcm 1 module see wiring diagram fig.
Intelligent Control Panel Slc Ppt Video Online Download
Notifier control module wiring diagram. Our notifier cmx 2 addressable control module in new condition comes with a warranty of 90 days and fast shipping via ups. This module is intend ed for power limited wiring only. Addressability allows the fcm 1a to be acti vated either manually or through panel programming on a select zone or area of coverage basis. 5 for frm 1 general fcm 1 control module the fcm 1 addressable control module provides notifier intelligent control pan els a circuit for notification appliances horns strobes speak ers etc or to monitor a telephone circuit. Addressability al lows the fcm to be activated either manually or through. All wiring shown is supervised and power limited.
Notifier cmx 2 control module wiring diagram division of pittway corporation mmx 1a monitor module cmx 2a refer to the appropriate notifier installation manual for detailed system information. Set the address on the module per job drawings. Trol module provides notifier intelligent fire alarm control pan els a circuit for notification appliances horns strobes speakers etc. Scs 8 fan control module annunciator. Install module wiring in accordance with the job drawings and appropri ate wiring diagrams. Set the address on the module per job drawings.
Smaller size fits inside devices or junction boxes. Notifiers intelligent addressable control module provides supervised monitoring of wiring to load devices that require an external power supply to operate such as horns strobes or bells. Page 5 wiring diagrams this page. Typicalnotifier system control panel only list available from notifier. Install module wiring in accordance with the job draw ings and appropriate wiring diagrams. In addition this module is intended for powerlimited wiring only.
Install contact closure devices per manufacturers installation instructions. All wiring must conform to applicable local codes ordinances and regulations. The frm 1a addressable relay. Fmm 1 monitor module class a supervised wiring to the monitored device. Break wire run to provide supervision. Some control panels have relay built in and do not require external wiring.
One relay required for each circuit. Fzm 1 zone interface monitor module transmits the status of one zone of 2 wire detectors to the fire alarm control panel. Refer to notifier manual. To next control module or end of line relay. Some panels support. Notifier cmx 2 addressable control.
Intelligent addressable control module and relay with built in type identification for onyx series panels. Module polarities are shown in alarm connect modules to listed compatible 32 vdc max. Fmm 1 connect modules to listed compatible notifier control panels only. Refer to the appropriate notifier control panel installation note. Fmm 101 mini monitor module class b supervised wiring to the monitored device. Any number of ul listed contact closure devices may be used.
Some panels support this module can be used to replace a cmx 2 mod a ule thatdisconnect power to the control panel before installing the modules.